Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13670525
| No.13670525
- Product Categories
- Friendly Links
| Information Name: | Shanghai Ming crown sidestream circulating water processor |
| Published: | 2015-03-21 |
| Validity: | 365 |
| Specifications: | DN80 ~ DN800 |
| Quantity: | 100000.00 |
| Price Description: | |
| Detailed Product Description: | I. Introduction || next PL-Series flow circulating water processor is based on the original full-flow water processor based on the development of next-generation products, the product uses the principle of low-voltage electric field pulse is automatically adjusted according to changes in water quality work output signal. After the water processor, reduce aggregation of water molecules, changes in the structure, the dipole moment of water molecules increases, the polarity increases, the surface tension increases, thereby increasing the capacity of the water soluble dirt molecules, to achieve the purpose of cleaning. In the role of the lower electrode, the processor generates a large number of tiny crystals with excellent scaling function, these crystals can be removed by the water into the dirt ions, forming loose aragonite crystals, the automatic drain valve excluded. After processor treated water, dissolved oxygen get activated under electrolysis electrodes produce large amounts of water OHˉ, O2ˉ, H2O2 and a large number of reactive oxygen species, those with strong oxidizing substances, can completely kill microorganisms in water and various algae, so as to achieve excellent algae sterilization function, prevent the formation of scale. Meanwhile, a large number of reactive oxygen species generated by the processor to the system wall further oxidation, forming a dense oxide film, such as iron oxide oxide film, the system blunt wall flower, thus inhibiting the corruption of the pipeline, increasing the system hair life, to equipment corrosion effect. Second, the technical parameters of the input power supply: 220V, 50Hz Operating voltage: <36V Water temperature: 0 ℃ ~ 95 ℃ head loss: 4 ~ 7m resistance after cleaning efficiency: 99% sterilization rate:> 99% algae rate:> 97% of the corrosion rate: up to the national standard applicable water quality: total hardness as CaCO3: <700mg / L three, F-type (for closed loop water system) Selection Area Dimensions Dimensions details over size head loss m maximum power w Weight Kg Model Model Diameter mm length L mm width W mm height H mm A mm B mm C mm D mm E mm F mm diameter and export mm diameter outfall mm PL-1 F 80 1200 600 1200 620 350 590 440 310 180 25 * 25 6 ≤90 160 PL-2 F 100 1200 600 1200 620 350 590 440 310 180 25 * 25 6 ≤120 160 PL-3 F 150 1200 600 1200 620 350 590 440 310 180 25 * 25 6 ≤ 160 165 PL-4 F 200 1200 600 1200 620 350 590 440 310 180 25 * 25 6 ≤200 170 PL-5 F 250 1200 600 1200 620 350 590 440 310 180 25 * 25 6 ≤300 172 PL-6 F 300 1200 650 1200 620 350 590 440 310 180 32 * 25 4 ≤500 180 PL-7 F 350 1200 650 1200 620 350 590 440 310 180 32 * 25 7 ≤600 180 PL-8 F 400 1450 720 1200 630 350 590 440 310 180 40 * 25 5 ≤800 185 PL-9 F 450 1450 720 1200 630 350 590 440 310 180 40 * 25 7 ≤900 186 PL-10 F 500 1500 730 1200 640 365 590 440 310 180 50 25 4.5 ≤1100 190 PL- 11 F 600 1500 730 1200 640 365 590 440 310 180 50 25 5 ≤1300 195 PL-12 F 700 1700 740 1200 850 395 590 440 310 180 65 25 4 ≤1500 198 PL-13 F 800 1700 740 1200 850 395 590 440 310 180 65 25 5 ≤1800 200 V. PL-Ⅱ beside the water processor selection A, open cooling water system should choose the F-type, according to the diameter of the F-type specifications indicated water processor choice. B, closed loop water system should be selected G-type, diameter according to the specifications indicated G-type water processor choice. Six, next to PL-Ⅱ water processor design and installation of water beside PL-Ⅱ processor design working pressure 1.6Mpa, the special needs of customers can be specially designed according to the actual situation. When designed and installed around the system pump should be given the space reserved for the installation of the processor, the processor and system intake pump outlet pipe connections, inlet and outlet connections processor system pump (eg installation diagram below) processor external power supply for 220V, 50Hz common power supply, processor installed indoors in dry and ventilated place. The new system can be directly installed processor, for scaling serious old system before installing the processor pipeline must be cleaned before they can be installed so as not to clog the pipeline off the scale. Seven, next to the PL-Ⅱ water processor service company products in the factory have to undergo a rigorous technical testing to ensure that each piece of equipment is the ultimate test of qualified products, the company sold products to provide one year of free maintenance and lifetime maintenance. Equipment failure in the operation of the company to ensure that give an answer within 48 hours. |
Admin>>>
You are the 6964 visitor
Copyright © GuangDong ICP No. 10089450, Valve Co., Ltd. Shanghai Ming crown All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 6964 visitor
Copyright © GuangDong ICP No. 10089450, Valve Co., Ltd. Shanghai Ming crown All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

